Property (Symbol) unit | Division | Initial Permeability (µi) | Saturation Flux Density (Bsat) gauss | Loss Factor [@frequency] (tanδ/µi) 10-6 | Curie Temp. (Tc) °C | Volume Resistivity (ρ) Ω-cm | Recommended Frequency (f) MHz | Application Area | Available As | Datasheet |
---|---|---|---|---|---|---|---|---|---|---|
M5 | NMG | 7.5 | 1750 | <3500 [100MHz] | 320 | 107 | 0.1-400 | filter, transformer | pressed extruded machined | M5 |
M4 | NMG | 12 | 1800 | <850 [10MHz] | 500 | 109 | 0.1-400 | filter, transformer | pressed extruded machined | M4 |
N40 | CMI | 15 | 2500 | <3850 [50MHz] | 600 | 1010 | 0.1-100 | inductive devices requiring high Q | pressed extruded machined | N40 |
M3F | NMG | 20 | 1800 | <500 [100MHz] | 400 | 109 | 0.1-100 | filter, transformer | pressed | M3F |
M3 | NMG | 20 | 2500 | <500 [100MHz] | 500 | 107 | 0.1-400 | antenna, filter, transformer | pressed extruded machined | M3 |
M2 (aka FRX P) | NMG FRX | 40 | 2300 | <150 [50MHz] | 450 | 107 | 0.1-50 | antenna, filter, transformer | pressed extruded machined | M2 |
C2075 | CMI | 50 | 3000 | <3950 [30MHz] | 420 | 109 | 0.1-40 | inductive transformers, transmission line coupled transformers up to 800 MHz, H field antennas | pressed machined | C2075 |
XTH2 | CMI | 80 | 3600 | <7200 [50MHz] | 300 | 108 | 0.1-50 | applications requiring high Q, temperatures up to 200 °C | pressed machined | XTH2 |
C2050 | CMI | 100 | 3700 | <4250 [10MHz] | 340 | 109 | 0.1-40 | inductive transformers, transmission line coupled transformers up to 800 MHz, H field antennas | pressed machined | C2050 |
M | NMG | 125 | 2400 | <40 [2.5MHz] | 350 | 107 | 0.1-25 | suitable for fixed frequency operation at 13.56 MHz with high Q, inductive & transmission line coupled transformers in 5 to 50 MHz range and EMI suppression > 200 MHz | pressed extruded machined | M |
XCK (aka FRX K) | CMI FRX | 125 | 2500 | <410 [2.5MHz] | 350 | 109 | 0.1-25 | a high density version of M, suitable for fixed frequency operation at 13.56 MHz with high Q, inductive & transmission line coupled transformers in 5 to 50 MHz range and EMI suppression > 200 MHz | pressed machined | XCK |
C2025 | CMI | 175 | 3900 | <1200 [10MHz] | 270 | 1010 | 10-750 | transformers, power supplies and linear amplifiers | pressed machined | C2025 |
N | NMG | 250 | 3000 | <100 [2.5MHz] | 250 | 108 | 0.1-4 | filter, transformer | pressed extruded | N |
C2010 | CMI | 340 | 3900 | <1400 [10MHz] | 245 | 107 | 10-500 | transformers, power supplies and linear amplifiers | pressed machined | C2010 |
G4 | NMG | 400 | 4600 | <35 [0.1MHz] | 250 | 108 | 0.1-10 | antenna, filter, transformer | pressed | G4 |
CMD10 | CMI | 625 | 4300 | <135 [1MHz] | 250 | 1010 | 0.1-10 | broad band RF & transmission line transformers, pulsed power and kicker magnets | pressed machined | CMD10 |
H (aka FRX J, impedance rated) | NMG FRX | 850 | 2950 | <250 [1MHz] | 135 | 105 | 20-250 | EMI suppression | pressed | H |
CN20 (aka FRX J, inductance rated) | CMI FRX | 925 | 4000 | <100 [1MHz] | 185 | 1010 | 0.5-30 | EMI suppression, BB linear transformers for RF amplifiers, hybrid transformers | pressed machined | CN20 |
CN20B | CMI | 1375 | 3500 | <25 [1MHz] | 160 | 108 | 1.5-30 | broad band, inductive coupled transformers, common mode chokes and suppression applications | pressed machined | CN20B |
CMD5005 (aka FRX G) | CMI FRX | 2100 | 3300 | <250 [1MHz] | 130 | 1010 | 1-100 | general purpose HF, deflection magnets for particle accelerators | pressed machined | CMD5005 |